欧美bbbwbbbw肥妇,免费乱码人妻系列日韩,一级黄片

Fan 4 speed may change depending on system configuration and option card install

  發(fā)布時間:2016-04-13 21:30:06   作者:佚名   我要評論
今天在配置服務器的時候因為清空了bios所以出現(xiàn)了如此提示Fan 4 speed may change depending on system configuration and option card install,經(jīng)過搜索雖然不是最終的解決方法, 但好像是6i陣列卡需要設置一下
The Fan 4 message will show if there's a PCI add-on card installed in the R410. It will display for about 3 seconds and then POST should continue, it should not cause POST to stop at the F1/F2 error message.


Dell PowerEdge R410: System asks to press F1 or F2

We just installed an option card (PERC 6/i) into a brand-new Dell PowerEdge R410 and now the system does no unattended startup but instead asks me to press F1 to continue or F2 to enter system setup after printing the following message on the console:

Fan 4 speed may change depending on system configuration and option card install.

Great forensic work, Mike!

Sorry to hear about your trouble with your PERC 6/i Adapter

Is your replacement PERC 6/I at the same firmware level as your original adapter ( 6.3.3-0002, 1.22.52-1909)? Link to PERC 6/I Firmware

Since your VDs show up as optimal, and you do not get error messages during POST regarding your storage controller / VDs, we can skip this:
From PERC BIOS (CTRL-R during POST) Main Menu VD Mgmt Screen:
1. Press CTRL-N to navigate to PD Mgmt Screen
2. Check hard drive information (# of hard drives listed, drive status).

Please try checking data consistency:

Perform the following steps to run a Consistency Check (this is non-destructive).
1. From within PERC BIOS (CTRL-R during POST), Press <Ctrl><N> to access the VD Mgmt menu
screen.
2. Press the down arrow key to highlight Virtual Disk #.
3. Press <F2> to display the menu of available actions.
4. Press the down arrow key to select Consistency Check.
5. Press the right arrow key to display the menu of available actions, Start and Stop.
6. Select Start and press <Enter> to run a Consistency Check.
The Consistency Check runs and checks the redundancy data in the virtual disks.
7. After you start the Consistency Check, press <Esc> to display the previous menu.


For your initial issues with drives not detected, please check that boot support is enabled:
1. From PERC BIOS, Press <Ctrl><N> to access the Ctrl Mgmt menu screen.
2. Press <Tab> to move the cursor to Enable Controller BIOS in the Settings box.
3. Press the spacebar to select Enable Controller BIOS. An X displays beside Enable Controller BIOS.
4. Press <Tab> to move the cursor to the Apply button, and then press <Enter> to apply the selection.

Try to check your Windows partition using diskpart (there is a 'RECOVER' option that you can consider).

如果出現(xiàn)了這提示,又恰巧出現(xiàn)了需要按F1或F2提示才能進入系統(tǒng),大家要注意了Fan 4 speed may change depending on system configuration and option card install并不影響到需要按F1或F2,肯定是前面別的錯誤提示信息。一般來說是因為機器PCI卡安裝了6i陣列卡的原因。
等腳本之家小編再測試一下具體的額設置方法以后再補充。反正現(xiàn)在就是不是Fan 4 speed may change depending on system configuration and option card install的問題導致無法進入系統(tǒng)的原因就對了。

相關(guān)文章

最新評論